| Model | AFC-33006 | AFC-33010 | AFC-33015 | AFC-33020 | AFC-33030 | AFC-33045 | AFC-33060 | AFC-33075 | | Capacity (kVA) | 6 | 10 | 15 | 20 | 30 | 45 | 60 | 75 | | Circuit Type | IGBT/PWM type | | Input | Phase | Three phase | | Wave | SINE WAVE | | Voltage | 220V/380V | | Voltage range | 220V/380V¡À15% | | Frequency range | 50Hz¡À3Hz »ò 60Hz¡À3Hz | | Power factor | 0.9 | | Output | Phase | Three phase | | Wave | SINE WAVE | | Voltage | Low | 5V-150V£¨L-N£© | | High | 10V-300V£¨L-N£© | | Frequency | 47~63Hz Adjustable£¬50Hz£¬60Hz£» 2F£¬4F£¬400Hz£¨Option£© | | Frequency regulation | ¨Q0.01% | Max. current | High (A) | 8.3 | 13.9 | 20.8 | 27.8 | 41.7 | 62.5 | 83.3 | 104.2 | | Low (A) | 16.7 | 27.8 | 41.7 | 55.6 | 83.3 | 125.0 | 166.7 | 208.3 | | System | Line regulation | £¼1% | | Load regulation | ¡À1% (linear load) | | Total harmonic distortion (THD) | 2% (linear load) | | Efficiency | ¨R90% | | Response time | ¨Q2ms | | Wave factor | 3:1 | Protection device | Input no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system | | Indicator | Display | LED | | Voltage | Show range: 0~600V, analytic degree: 0.1V, accurate degree: 0.15%FS+4COUNT | | Current | Show range: 0~700A, analytic degree: 0.01A(<100A)/0.1A(¡Ý100A), accurate degree: 0.2%FS+4COUNT | | Power | Show range: 3kW~75kW, analytic degree: 0.01kW(<10kW)/0.1kW(¡Ý10kW), accurate degree: 0.3%FS+4COUNT | | Frequency | Show range: 0~999.9Hz, analytic degree: 0.1Hz, accurate degree: 0.1% | | Environment | Insulation resistance | DC500V ¨R 20M¦¸ | | Withstand voltage insulation | AC 1800V 5mA/ 1Min | | Cooling system | Fan cooling | | Temperature | 0¡æ~40¡æ | | Humidity | 0~90% (Non-condensing) | | Altitude | ¨Q 1500m | | Case No. | ¢Û ¡¡ | ¢Ü¡¡ | ¢Ý | | Weight(kg) | 200 | 230 | 300 | 310 | 390 | 550 | 580 | 670
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
One key for shutdown when fault.
Quick response speed. Response time ¡Ü2ms.
High accurate measurement for parameter: Voltage, 0.15%FS+4COUNT; Current, 0.2%FS+4COUNT; Frequency, 0.1%; Power, 0.3%FS+4COUNT.
Output voltage: 5~300V continuous adjustable. Quick & convenient 3 scales of preset voltage for high and low voltage simulation: High: +10%~+25% of preset voltage; Medium: preset voltage; Low: -10%~-30% of preset voltage.
Pure output sine-wave. (Please see specification table).
Well protection and fault alarm function: Input no-fuse breaker; electronic circuit instant trip for over voltage, over current, over load, over temperature and short circuit protection and alarm system.
Power module design patent.
|
|
 |
 |
 |
 |

|