DC OUTPUT
|
| |
CH1, CH2
|
CH3
|
|
| Voltage |
|
| Current |
|
| Tracking Series Voltage |
|
| Tracking Parallel Current |
|
|
CONSTANT VOLTAGE OPERATION
|
| Line Regulation |
≦0.01% + 3mV |
| Load Regulation |
≦0.01% + 3mV (rating
current≦3A)
≦0.02% + 5mV (rating current >3A) |
| Ripple & Noise |
≦1mVrms 5Hz ~ 1MHz |
| Recovery Time |
≦100μS ( 50% Load change,
Minimum load 0.5A ) |
| Temp. Coefficient |
≦300ppm/°C |
| Output Range |
0 to rating voltage
continously adjustable |
|
CONSTANT CURRENT OPERATION
|
| Line Regulation |
≦0.2% + 3mA |
| Load Regulation |
≦0.2% + 3mA |
| Ripple Current |
≦3mArms |
| Output Range |
0 to rating current
continously adjustable |
|
TRACKING OPERATION
|
| Parallel Regulation |
Line Regulation≦ 0.01% + 3mV
Load Regulation≦ 0.01% + 3mV (rating current≦3A)
Load Regulation≦0.02% + 5mV (rating current >3A)
|
| Series Regulation |
Line Regulation≦0.01% + 5mV
Load Regulation≦300mV
Tracking Error≦ 0.5% ± 10mV (10 ~ 30V no load)
(with load added≦300mV)
Tracking Error≦0.5% ± 30mV (0 ~ 9.99V no load)
(with load added≦300mV) |
|
CH3 OPERATION
|
| Output Voltage |
2.5V/3.3V/5V ±8% |
| Output Current |
3A |
| Line Regulation (25±5°C) |
≦5mV |
| Load Regulation (25±5°C) |
≦15mV |
| Ripple & Noise |
≦2mVrms |
|
METER
|
| Display |
Voltage: 2 3/4 digits 0.4"
LED display
Current: 2 3/4 digits 0.4" LED display |
| Voltage Resolution |
100 mV |
| Current Resolution |
10 mA |
| Program Accuracy (25±5°C) |
Voltage: ±(0.05% of RDG + 2
digits)
Current: ±(0.05% of RDG + 2 digits) |
| Readback Accuracy (25±5°C) |
Voltage: ±(0.05% of RDG + 2
digits)
Current: ±(0.05% of RDG + 2 digits) |
|
KEY LOCK
|
| |
Yes |
|
MEMORY SAVE/RECALL
|
| |
4 sets |
| POWER
SOURCE |
|
| |
AC 100V/120V/220V/230V ±10%,
50/60Hz |
|
ACCESSORIES
|
| |
User manual x 1
Power cord x 1
European test lead GTL-203 x 1, GTL-204 x 2 |
| DIMENSIONS & WEIGHT |
| |
210(W) x 130(H) x 265(D)mm,
Approx. 7kg |