| Waveforms |
|
|
|
|
| Sine, Square, Triangle, Ramp, ±Pulse |
|
|
| Range |
|
|
|
|
|
| 0.5Hz to 4MHz in 6 ranges |
|
|
| Tuning Range |
|
|
|
|
| Variable Multiplication factor of 0.04 to 4.0 of selected
range |
|
|
| Resolution |
|
|
|
|
| 0.001Hz (model 4003A only) |
|
|
| Operating Modes |
|
|
|
|
| Normal, Sweep, VCF |
|
|
| Frequency Stability |
|
|
|
|
| Output will change less than 0.1% for 15 minutes after
switching ON and it will change less than 0.2% for 24 Hours after switching
ON. |
|
|
| Output Characteristics |
|
|
| Impedance |
|
|
|
|
| 50Ω±2% |
|
|
|
| Level |
|
|
|
|
|
| Variable control |
| From |
|
| 0.1Vp-p (No Load) |
| 0.05Vp-p (50Ω Load) |
| To |
|
| 20Vp-p (No Load) ±1Vp-p |
| 10Vp-p (50Ω Load) ±0.5Vp-p |
|
|
| Attenuation |
|
|
|
|
| -20dB ±2% |
|
|
| DC Offset |
|
|
|
|
|
| Variable: ±10V open circuit, ±5V into 50Ω |
|
|
| Sine Wave |
|
|
| Distortion |
|
|
|
|
|
| Less than 2% (1Hz - 100kHz) |
|
|
| Harmonic Ratio |
|
|
|
|
| <30dB, 100kHz to 4MHz |
|
|
| Frequency Response |
|
|
|
|
| <0.1dB, upto 100kHz |
| <1dB, 100kHz to 4MHz |
|
|
| Triangular Wave |
|
|
| Symmetry |
|
|
|
|
| 50% (Positive Half) to 50% (Negative Half) |
| <2%, 1Hz to 100kHz |
|
|
| Ramp Wave |
|
|
| Frequency Range |
|
|
|
|
| 0.5Hz to 3.5MHz |
|
|
| Symmetry |
|
|
|
|
| 80% (Rise Wave) to 20% (Fall Wave) |
| <5%, 1Hz to 100kHz |
|
|
| Rising Wave linearity |
|
|
|
|
| <2%, 1Hz to 100kHz |
|
|
| Square Wave |
|
|
| Symmetry |
|
|
|
|
| 50% (Positive Half) to 50% (Negative Half) |
| <2%, 1Hz to 100kHz |
|
|
| Rise Time |
|
|
|
|
|
| <90nS, (20Vp-p, No Load) |
|
|
| Positive Pulse |
|
|
| Frequency Range |
|
|
|
|
| 0.5Hz to 3.5MHz |
|
|
| Symmetry |
|
|
|
|
| 20% to 80%, |
| <5%, 1Hz to 100kHz |
|
|
| Rise Time |
|
|
|
|
|
| <90nS, (20Vp-p, No Load) |
|
|
| Negative Pulse |
|
|
| Frequency Range |
|
|
|
|
| 0.5Hz to 3.5MHz |
|
|
| Pulse Width |
|
|
|
|
| 15% of time period of the Set Frequency |
|
|
| Symmetry |
|
|
|
|
| 80% to 20%, <5%, 1Hz to 100kHz |
|
|
| Rise Time |
|
|
|
|
|
| <90nS, (20Vp-p, No Load) |
|
|
| Synchronous Output |
|
|
| Impedance |
|
|
|
|
| 50Ω ±2% |
|
|
|
| Level (TTL) |
|
|
|
|
| Approx. 3Vp-p fix amplitude |
|
|
| Level (CMOS) |
|
|
|
|
| Adjustable 5V to 14.5Vp-p (±0.5 Vp-p) |
|
|
| Rise Time (TTL) |
|
|
|
|
| <60nS |
|
|
|
| Rise Time (CMOS) |
|
|
|
|
| <90nS |
|
|
|
| VCF Input (model 4003A only) |
|
|
| Input Level |
|
|
|
|
| 0 to 10V |
|
|
|
| Input Frequency |
|
|
|
|
| DC to 1kHz |
|
|
| Sweep Operation |
|
|
| Operating Mode |
|
|
|
|
| Linear/ LOG |
|
|
| Sweep Rate |
|
|
|
|
| 5 sec to 25ms |
|
|
| Width |
|
|
|
|
|
| 1:1 to 1:100 |
|
|
| Sweep Synchronous Output |
|
|
| Output waveform |
|
|
|
|
| Linear/ LOG ramp wave |
|
|
| Amplitude |
|
|
|
|
|
| 10Vp-p (No Load) +/- 0.8Vp-p |
|
|
| Frequency Counter (model 4003A only) |
|
|
| Display |
|
|
|
|
|
| 5 digit, Auto range |
|
|
| Display Unit |
|
|
|
|
| Hz/ kHz auto range |
|
|
| Resolution |
|
|
|
|
| 0.01Hz (max.) |
|
|
| Accuracy |
|
|
|
|
|
| <0.02% ±1 digit |
|
|
| Temp coefficient |
|
|
|
|
| <10PPM / °C |
|
|
| External Counter (model 4003A only) |
|
|
| Max. Input Voltage |
|
|
|
|
| <150mV rms |
|
|
| Input Frequency |
|
|
|
|
| 0.1Hz to 60MHz |
|
|
| Coupling |
|
|
|
|
|
| HF - for more than 100kHz |
| LF - With 100kHz filter for less than 100kHz |
|
|
| Sensitivity |
|
|
|
|
|
| <30mV rms (1MHz) |
|
|
| Power Source: 115V AC ±10%, 50/60Hz, fuse 600mA or |
|
230V AC ±10%, 50/60Hz, fuse 300mA |
|
|
| Operating Environment |
|
|
| Temperature |
|
|
|
|
| 0 to 40°C |
|
|
|
| Humidity |
|
|
|
|
|
| 10% to 80% |
|
|
| Storage |
|
|
|
| Temperature |
|
|
|
|
| -20°C to 70°C |
|
|
| Humidity |
|
|
|
|
|
| 0% to 90% |
|
|
| Dimensions (W x H x D): 11 x 3.6 x 11.9'' (275 x 90 x 300
mm) |
|
|
| Weight: 5.5 lbs. (2.5 Kg) |