| DC Volts |
| Ranges 340 mV, 3.4 V, 34 V,
340 V, 1000V |
| Resolution 0.1 mV, 1 mV, 10
mV, 100 mV, 1 V |
| Accuracy ±(1.0 % rdg + 2
dgts) |
| Input Impedance 340 mV:
>100 MΩ; 3.4 V: 10 MΩ; 34 V to 1000 V: 9.1 MΩ |
| Overload Protection 1000 VDC
or 750 VACrms |
| AC Volts (50 Hz-500 Hz) True
RMS |
| Crest Factor <3 |
| Ranges 3.4 V, 34 V, 340 V,
750 V |
| Resolution 1 mV, 10 mV, 100
mV, 1 V |
| Accuracy 3.4 V & 34 V
ranges: ±(2.0 % rdg + 8 dgts) |
| 340 V & 750 V ranges:
±(2.0 % rdg + 8 dgts) |
| Input Impedance 3.4 V: 10 MΩ;
34 V to 1000 V: 9.1 MΩ |
| Overload Protection 1000 VDC
or 750 VACrms |
| DC Current |
| Ranges 340 uA, 3400 uA, 34
mA, 340 mA, 10 A |
| Resolution 0.1 uA, 1 uA,
10uA, 100 uA, 10 mA |
| Accuracy 340 uA to 340 mA
ranges: ±(2.0 % rdg + 2 dgts) |
| 10 A range: ±(3.0 % rdg + 3
dgts) |
| Input Protection 0.5 A/500 V
& 10 A/600 V fast blow ceramic fuses |
| 10A Input 10 A for 60 sec
max. followed by a 10 minute cooling period |
| AC Current (50 Hz-500 Hz)
True RMS |
| Crest Factor <3 |
| Ranges 340 uA, 3400 uA, 34
mA, 340 mA, 10 A |
| Resolution 0.1 uA, 1 uA,
10uA, 100 uA, 10 mA |
| Accuracy 340 uA to 340 mA
ranges: ±(2.5 % rdg + 10 dgts) |
| 10 A range: ±(3.5 % rdg + 10
dgts) |
| Input Protection 0.5 A/500 V
& 10 A/600 V fast blow ceramic fuses |
| 10A Input 10 A for 60 sec
max. followed by a 10 minute cooling period |
| Resis tance |
| Ranges 340 Ω, 3.4 kΩ, 34 kΩ,
340 kΩ, 3.4 MΩ, 34 MΩ |
| Resolution 0.1 Ω, 1.0 Ω, 10
Ω, 100 MΩ, 1 kΩ, 10 kΩ |
| Accuracy 340 Ω to 340 kΩ
ranges: ±(1.5 % rdg + 4 dgts) |
| 3.4 MΩ range: ±(2.5 % rdg + 4
dgts) |
| 34 MΩ range: ±(5.0 % rdg + 5
dgts) |
| Open Circuit Voltage
(typical) -0.45 VDC (-1.2 VDC on 340 Ω range) |
| Overload Protection 500
VDC/ACrms |
| Diode Te st |
| Test Current 1.0 mA (typical) |
| Resolution 10 mV |
| Accuracy ±(3.0 % rdg + 3
dgts) |
| Audible Indication <0.25 V |
| Open Circuit Voltage 3.0 VDC
(typical) |
| Overload Protection 500
VDC/ACrms |
| Continuity |
| Audible Indication Less than
35 Ω |
| Response Time 500 ms |
| Overload Protection 500
VDC/ACrms |
| General |
| Display 3 3/4 digit, 3400
count LCD with 34 segment analog bar graph |
| Polarity Automatic, positive
implied, negative polarity indication |
| Overrange OL or -OL is
displayed |
| Low Battery Indication The
battery symbol will display when battery voltage drops below |
| operating levels |
| Measurement Rate 2 times per
second (12 times per second for analog bar graph) |
| Auto Power Off Approximately
10 minutes |
| Operating Environment 0ºC to
50ºC at <70 % relative humidity |
| Storage Environment -20ºC to
60ºC at 0 to 80 % relative humidity |
| Accuracies Stated accuracy at
23ºC +5ºC at <75 % relative humidity |
| Temperature Coefficient 0.1 x
(specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC) |
| Power Single standard 9 volt
battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life 150 hours
typical |
| Dimensions 165 mm (H) x 78 mm
(W) x 42.5 mm (D) |
| Weight Approximately 10.3 oz.
(377 g) with battery and hanger |